Explanatory document to ECE/TRANS/WP.11/2018/15 Transmitted by the Government of Finland INF.12 Economic Commission for Europe Inland Transport Committee Working Party on the Transport of Perishable Foodstuffs Seventy-fourth session Geneva, 8-12 October 2018 Item 5 (f) of the provisional agenda Status and implementation of the Agreement on the International Carriage of Perishable Foodstuffs and on the Special Equipment to be Used for such Carriage (ATP): interpretation of ATP 3 October 2018 Explanatory document to TRANS/WP.11/2018/15 Proposed amendment to Annex 1, Appendix 2, Paragraph 6.5: Cool down test, measuring the outside temperature Unstable outside conditions, example data and figure: Cool down time from the initial temperature 16.0 °C to the class temperature -20.0 °C is 4:10 (250 min) Three different interpretations: (a) "Coldest point outside" when class temperature has been reached, 21.0 °C  max cool down time 4:30 (270 min)  PASS (b) "Coldest point outside" over the whole cool down, 16.0 °C  max cool down time to 3:40 (220 min)  FAIL (c) Mean outside temperature over the whole cool down, 20.9 °C  max cool down time 4:30 (270 min) (note 20.9 is rounded to 21)  PASS Depending on the interpretation, the result could be PASS or FAIL. For example in class FRC each degree of C represents 10 minutes in allowed cool down time. -20.0 °C, "warmest point inside" at 4:10 (250 min) Condenser air inlet (a) 21.0°C, "coldest point outside" at 4:10 (250 min) (c) Mean outside temperature 20.9 °C over the whole cool down until -20.0 °C inside has been reached (b) 16.0 °C, "coldest point outside" Outer wall Inside rear Inside front (a), (c) (b) Stable outside conditions, example data and figure: Cool down time from the initial temperature 20.0 °C to the class temperature -20.0 °C is 4:10 (250 min) Three different interpretations: (a) "Coldest point outside" when class temperature has been reached, 19.8 °C  max cool down time 4:20 (260 min) (note 19.8 is rounded to 20)  PASS (b) "Coldest point outside" over the whole cool down, 19.6 °C  max cool down time to 4:20 (260 min) (note 19.6 is rounded to 20)  PASS (c) Mean outside temperature over the whole cool down, 20.0 °C  max cool down time 4:20 (260 min)  PASS No remarkable differences between interpretations if outside temperature remains stable. *** -20.0 °C, "warmest point inside" at 4:10 (250 min) Condenser air inlet (a) 19.8 °C, "coldest point outside" at 4:10 (250 min) (c) Mean outside temperature 20.0 °C over the whole cool down until -20.0 °C inside has been reached (b) 19.6 °C, "coldest point outside" Outer wall Inside rear Inside front (a), (b), (c)